H.D.S. Copper

H.D.S. Copper trunk cable 6x RJ45 with LED signaling

EasyLan® High Density System (H.D.S.) Kupfer Panel Montage

If you would like to watch our YouTube video, please activate the “Marketing” option in the cookie consent section of our privacy policy.

Change consent

alternatively watch video on YouTube

The H.D.S. copper trunk cable is designed for cabinet to cabinet connections and for the connection of consolidation points. The preterminated solution with six RJ45 connections in the trunk cable is designed for 10 Gigabit Ethernet transmissions and is in accordance with class EA as per ISO/IEC 11801 or EN 50173. The cables are preterminated on both sides with six port H.D.S. modules and available in any length up to 60 meters. The associated remote end of the wire can be easily located during operation using the integrated LED signaling.

GHMT Type Approval Certification as PDF Download

Download

Datasheets as PDF Download

Download H.D.S. Copper trunk cable 6x RJ45 Cat. 7 AWG23/1 Dca

Download H.D.S. Copper trunk cable 6x RJ45 Cat. 7 AWG23/1 B2ca

Download H.D.S. Copper trunk cable 6x RJ45 Cat. 7 AWG26/1 Dca

Request a free sample

H.D.S. Copper trunk cable 6x RJ45 - 6x preLink® Termination

The H.D.S./preLink® trunk system is designed for copper connections in data centers. It is especially suited for cabinet to cabinet connections or for the connection to consolidation points. The preterminated solution with six RJ45 connections in a braided sleeve is designed for 10 Gigabit Ethernet transmissions and is in accordance with class EA as per ISO/IEC 11801 or EN 50173-1. The cables are delivered preterminated on both sides with 6-port H.D.S. modules and preLink® terminal blocks, the Y-connector length on the preLink® module side can be freely selected. The H.D.S. preLink® trunk cables are delivered bundled in any length up to 45 meters (individual cables up to 90 m) together with test protocols. After the cable installation, the H.D.S. 6-port module can be mounted in an H.D.S. installation frame in the distribution cabinet or the floor tank. The preLink® terminal blocks can be mounted in the selected pre-Link® module (see section: preLink® module). It is possible to connect up to 168 RJ45 ports (H.D.S. side) in 3U or up to 18 ports (H.D.S. side) in an underfloor installation. The module housing can be opened for maintenance and the individual Keystone sockets can be exchanged without the need to cut the cable and to re-configure it.

Request a free sample

H.D.S. Copper trunk cable 6x RJ45 - 6x fixLink®

The High Density System Cu is designed for copper connections in data centers, it is especially suited for cabinet to cabinet connections or for the connection of consolidation points. The preterminated solution with six RJ45 connections in the 6-fold cable bundle is designed for 10 Gigabit Ethernet transmission and in accordance with class EA as per ISO/IEC 11801 or EN 50173-1. The cables are preterminated on both sides with six port H.D.S. modules and delivered in any length up to 45 meters. Test protocol is included. After the cable installation, the two 6-port modules can be mounted in an H.D.S. rack in the distribution cabinet or a floor tank. It is possible to connect up to 168 RJ45 ports in 3U or up to 18 ports in an underfloor installation.

Request a free sample

H.D.S. Copper trunk cable 6x RJ45 - 6x RJ45 DualBoot®

The H.D.S. system with a direct RJ45 connection provides a disentanglement of the server Ethernet connections to the connections at the network switches, especially in high density racks (e.g. IBM® iDataPlex® rack systems). The RJ45 sockets can be positioned directly at the height of the servers. This means that only short patch cables (e.g. PushPull) are required for the connection. Result: The maintainability of the network components increases significantly through better accessibility. The Ethernet cable harness is routed inside the rack to a large extent, which means that the space in traditional cabling areas is available for other cable types, e.g. InfiniBand. Optimal bending radii and adapted lengths permit an efficient use. Networks can be separated logically and physically through the free color selection, the allocation (switch port – server port) can be freely defined. For example, ports of two switches can be placed next to each other, to achieve the 1:1 correlation to the server. The H.D.S. panels can be freely mounted and upgraded as needed.

Request a free sample

H.D.S. Panel for H.D.S.-Fiber Optic und Copper Modules

Using the H.D.S. panels, you can fasten the H.D.S. fiber optic and H.D.S. copper modules in the patch field of the distribution cabinets. The H.D.S. panels are available in 19" 1U designs.

Datasheet as PDF Download

Download

Download

Request a free sample

H.D.S. Side Modul rack 3U / 14TE

H.D.S. side module carriers are 14HP wide 3U assembly car-riers for the insertion of H.D.S. modules. Up to 24 ports can be distributed to 2 individual modules. The slide-in modules can be pulled out completely. Units are fastened on thread plates. This permits a fast and easy installation. The mini-module carrier can be combined with H.D.S. modules.The side cabinet mounting makes it possible to realize a space saving, especially climate friendly cabling without disturbing the air flow.

Request a free sample

H.D.S. Blind Cover

Blind cover to close H.D.S. panel ports.

Datasheet as PDF Download

Download

Request a free sample

LED Detector / LED Detector Pro

LED Detector Pro
Detector for the feed into the H.D.S. trunks for the identification of the plug ends. The detector will be plugged into the intended contact pairs and the button will be actuated to activate the light at the patch cable. The selection of four operating modes is possible by repeated actuation. To charge the battery, the detector will be plugged into to a USB interface using the accompanying USB micro cable.

LED Detector
Detector for the feed into the H.D.S. trunks for the identification of the plug ends. The detector will be plugged into the intended contact pairs and the button will be actuated to activate the light at the patch cable. The selection of four operating modes is possible by repeated actuation. Batteries: 4 x button cells LR41.

Datasheet as PDF Download

Download LED Detector

Download LED Detector Pro

Request a free sample