Panels

Panel 19" 1U for 24 Keystone Modules straight outlet

Demontage RJ45 Keystone

If you would like to watch our YouTube video, please activate the “Marketing” option in the cookie consent section of our privacy policy.

Change consent

alternatively watch video on YouTube

The 19” 1U distribution panel can be fitted with up to 24 preLink®/fixLink® RJ45 Keystone modules. The modules are simply snapped in and sit flush in the front of the front panel. Alternatively, fiber optic or coax adapters can also be used. The distribution panel can be ordered in either stainless steel or powder-coated sheet steel.
The mounting material and the Keystone modules are not included in the scope of delivery.

Standards:

  • IEC 60 603-7-1

Properties:

  • Installation dimension 19“ 1U, depth 100mm for installation in 19” distribution rack
  • Front side Keystone standard break-out for 24 modules, labeled 1-24
  • Rear cable clip, separate fastening for each cable using cable ties
  • Potential equalization via earthing cable incl. 6.3mm x 0.8mm blade receptacle
  • Housing material: Powder-coated sheet steel gray RAL7035 or stainless steel
  • Materials in accordance with RoHS 2002/95/EC
  • Temperature range: -40°C to +70°C

Accessories:

  • Self-adhesive labeling strip for marking the ports, length 430mm
  • Screws and cage nuts, set for one panel
Description
Order code
preLink® / fixLink® Panel, 19'', 1U, 24x Keystone, RAL7035 CKVPL0101E
preLink® / fixLink® Panel, 19'', 1U, 24x Keystone, Stainless steel CKVPL020EE
Self-adhesive labeling strip, length 430mm, PU 5 pcs. AVZBTK430
Screws and cage nuts, set for one panel AVZ4SUKM

 

Datasheet as PDF Download

Download

fixLink® - System overview

Download

Request a free sample

Panel 19" 1U for 48 Keystone Modules straight outlet

The 19” 1U distribution panel can be fitted with up to 48 fixLink® Pro / fixLink® Pro+ RJ45 Keystone modules. The modules are simply snapped into place and sit flush in the front panel. The panel has 24 cut-outs, each of which can accommodate two modules, thus enabling the high packing density of 48 ports on one height unit.
The mounting material and the Keystone modules are not included in the scope of delivery.

Standards:

  • IEC 60 603-7-1

Properties:

  • Installation dimension 19“ 1U, depth 130mm for installation in 19” distribution rack
  • Front 24 cut-outs for a maximum of 48 fixLink® Pro / fixLink® Pro+ RJ45 Keystone modules
  • Rear cable clip, separate fastening per cable on 2 levels via cable ties
  • Potential equalization via earthing cable incl. 6.3mm x 0.8mm blade receptacle
  • Housing material: powder-coated sheet steel, gray RAL7035 or black RAL9005
  • Materials in accordance with RoHS 2002/95/EC
  • Temperature range: -40°C to +70°C

Accessories:

  • Screws and cage nuts, set for one panel
Description
Order code
fixLink® Pro/Pro+ Panel 19'' 1U, 48x Keystone, RAL7035 CKVFL0481E
fixLink® Pro/Pro+ Panel 19'' 1U, 48x Keystone, RAL9005 CKVFL0482E
Screws and cage nuts, set for one panel AVZ4SUKM

 

Datasheet as PDF Download

Download

fixLink® - System overview

Download

Panel 19" 0.5U for 24 Keystone Modules straight outlet

The 19" 0.5U panel can be equipped with up to 24 preLink® / fixLink® RJ45 Keystone modules. The compact design enables a high packing density of 48 ports per U, depending on the modules used. The modules are simply snapped into place and sit flush in the front panel. The distribution panel can only be ordered in stainless steel.
The mounting material and the Keystone modules are not included in the scope of delivery.

Standards:

  • IEC 60 603-7-1

Properties:

  • Installation dimension 19" 0.5U, depth 100mm for installation in 19" distribution rack
  • Front side Keystone standard break-out for 24 modules
  • Rear side Cable clip, separate fastening for each cable via cable ties
  • Potential equalization via earthing cable incl. flat plug sleeve 6.3mm x 0.8mm
  • Housing material: stainless steel
  • Materials in accordance with RoHS 2002/95/EC
  • Temperature range: -40°C to +70°C

Accessories:

  • Screws and cage nuts, set for two panels
Description
Order code
preLink® / fixLink® Panel 19" 0.5U 24x Keystone, stainless steel CKVPL5F0EE
Stainless steel labeling strips for 19" distribution panels CVZB5FEE
Screws and cage nuts, set for two panels AVZ4SUKM

 

Datasheet as PDF Download

Download

fixLink® - System overview

Download

Request a free sample

Panel 19" 1U for 24 Keystone Modules angled

The preLink® / fixLink® angled panel offers the option of snapping 24 Keystone modules into the panel at an angle of 30°. This automatically guides the patch cables to the side of the enclosure where they can be attached next to the patch level. There is no need for additional patch panels for cable routing.
The 30° angle panel requires less space to the front than conventional patch panels with straight modules due to the angled patch cables.
The distribution panel can be fitted with up to 24 preLink® / fixLink® RJ45 Keystone modules. It can be ordered in the versions 24 ports left, 24 ports right and 12 ports left / 12 ports right.
The mounting material and the Keystone modules are not included in the scope of delivery.

Standards:

  • IEC 60 603-7-1

Properties:

  • Installation dimension 19" 1U, depth 120mm for installation in 19" distribution rack
  • Front side Keystone standard break-out for 24 modules, labeling 1-24
  • Rear side Cable clip, separate fastening per cable via cable ties
  • Equipotential bonding via earthing cable incl. flat plug sleeve 6.3mm x 0.8mm
  • Material housing: powder-coated sheet steel grey RAL7035 
  • Materials in accordance with RoHS 2002/95/EC
  • Temperature range: -40°C to +70°C

Accessories:

  • Self-adhesive labeling strips for labeling 2 ports at a time. The labeling strips can be attached between the cut-outs. Length 32mm
  • Screws and cage nuts, set for one panel
Description
Order code
preLink® / fixLink® Angled panel, 19'', 1U, 24x Keystone, RAL7035, outlet 12 left / 12 right CKVPL0W01E
preLink® / fixLink® Angled panel, 19'', 1U, 24x Keystone, RAL7035, outlet 24 left CKVPL0L01E
preLink® / fixLink® Angled panel, 19'', 1U, 24x Keystone, RAL7035, outlet 24 right CKVPL0R01E
Self-adhesive labeling strips, length 32mm, PU 12 pcs AVZBTK032
Screws and cage nuts, set for one panel AVZ4SUKM

 

Datasheet as PDF Download

Download

fixLink® - System overview

Download

Request a free sample

Panel 19" 1U for 24 Keystone modules including labelling windows

The 19" 1U distribution panel can be fitted with up to 24 preLink® / fixLink® RJ45 Keystone modules and has a labeling window above each port. A labeling sheet with matching 12x33 mm cut-out is included.
The modules are simply snapped in and sit flush in the front of the front panel. Alternatively, fiber optic or coax adapters can also be used.
The mounting material and the Keystone modules are not included in the scope of delivery.

Standards:

  • IEC 60 603-7-1

Properties:

  • Installation dimension 19" 1U, depth 100mm for installation in 19" distribution rack
  • Front side Keystone standard break-out for 24 modules and 24 labeling windows
  • Rear side Cable clip, separate fastening for each cable via cable ties
  • Equipotential bonding via earthing cable incl. flat plug sleeve 6.3mm x 0.8mm
  • Housing material: powder-coated sheet steel grey RAL7035 or black RAL9005
  • Materials in accordance with RoHS 2002/95/EC
  • Temperature range: -40°C to +70°C

Accessories:

  • Screws and cage nuts, set for one panel
Description
Order code
Built-in panel 1U 19" for 24 modules, with labeling window, grey RAL 7035 CKVPL0B01E
Built-in panel 1U 19" for 24 modules, with labeling window, black RAL 9005 CKVPL0B02E
Perforated label sheet, white AZVBS10
Screws and cage nuts, set for one panel AVZ4SUKM

 

Datasheet as PDF Download

Download

fixLink® - System overview

Download

Labeling sheet as Excel template

Download

Request a free sample

Keystone F-coupling and blind cover as module replacement

F-coupling and blind cover as module replacement
The F-coupling is used to integrate coax cables into the preLink®/fixLink® patch panels and into the range of outlets. The preLink®/fixLink® blind cover can be used both in the distribution panel and in the outlets to cover unused ports.

Empty module for SC-S or LC-D as a module replacement
The empty modules for SC-S or LC-D couplings are used to integrate fiber optic connections, whereby special flangeless couplings (available on request) are required. The Keystone adapters are not suitable for installation in design-capable module holders (1-gang / 2-gang / 3-gang) and the 0.5U panel.

Description
Order code
F-coupling in keystone format for the integration of coax cables CKVZMFK1
Blind cover for Keystone break-out, white RAL9010 CKVZMB01
Keystone adapter (blind module) for LC-D / SC-S, white RAL9010 CKVZMLC1
Blind cover for Keystone break-out, black CKVZMB02

 

overview fixLink® - System