Panel 19'' 1U for 24 Keystone Modules straight outlet
The 19" 1U distribution panel can be loaded with up to 24 preLink® / fixLink® RJ45 Keystone modules. The panel has two levels. This positions the modules flush with the front panel. The distribution panel can be ordered in stainless steel or powder-coated iron sheet. Mounting material and Keystone modules are not included.
preLink® - System overview
Datasheet as PDF Download
Panel 19'' 0.5U for 24 Keystone Modules straight outlet
Angled Panel 30° 19" 1U for 24 Keystone modules
With the preLink®/fixLink® angled panel, the user has the option of clicking 24 keystone modules into the panel at an angle of 30°, and as a result the connected patch cables automatically run to the cabinet side and need only be attached laterally beside the patch level. This means the user can eliminate additional routing panels for cable routing. During operation, the angled panels with the flat front side and the side-facing patch cables also require less space than conventional patch panels with vertically installed ports. Mounting material and Keystone modules are not included!
preLink® - System overview
Datasheet as PDF Download
preLink® DC Panel 19" 1U, Cat. 6A ISO/IEC Cat. 6A EIA/ITA, Class EA, with L.E.O. Function
For the preLink® Data Center patch panel Cat. 6A EIA/ITA the data center modules come pre-mounted on a rail and need only be finalized with the relevant cable terminal block. Here, we particularly recommend the pre-assembled data center solutions, which may be ordered as single or multiple cable. The “Light-Emitting-Outlet“ (L.E.O.) allows you to easily identify matching cable ends using a detector. The connections on both sides can be made to emit light even in the case of patched data links. This function works with all common, shielded data cables. This works with all standard shielded data cables. Due to their slim design, the die-cast zinc socket modules are especially suitable for densely packed data center panels with up to 48 ports in 1U. Packaging unit: 1 pc. per box
preLink® - System overview
Datasheet as PDF Download
Panel 19" 1U for 24 Keystone modules including labelling windows
The 19" 1U description panel can be loaded with up to 24 preLink® / fixLink® RJ45 Keystone modules. The panel has two levels. This positions the modules flush with the front panel. Above every port there are labelling areas to mark the single ports. The pre-cut paper is included in delivery. In addition, an option exists to mark the individual ports using an attached 12x33 punched out labeling sheet.
Datasheet as PDF Download
preLink® - System overview
Labeling window as Excel template
preLink® DC Panel 19" 0,5U Cat. 6A ISO/IEC
For the preLink® Data Center patch panel Cat. 6A EIA/ITA the data center modules come pre-mounted on a rail and need only be finalized with the relevant cable terminal block. Here, we particularly recommend the pre-assembled data center solutions, which may be ordered as single or multiple cable. The connections on both sides can be made to emit light even in the case of patched data links. This function works with all common, shielded data cables. This works with all standard shielded data cables. Due to their slim design, the die-cast zinc socket modules are especially suitable for densely packed data center panels with up to 24 ports in 0,5U. Packaging unit: 1 pc. per box
preLink® - System overview
Datasheet as PDF Download
Panel 19" 1U for 24 preLink® Extender straight outlet